tocommon configuration rotary evaporator
Home » Rotary Evaporator » operation steps of rotary evaporators

operation steps of rotary evaporators

operation steps of rotary evaporators

the operating procedures

rotary evaporator

rotary evaporator

  1. Vacuum: After opening the vacuum pump, it was found that the vacuum could not be reached. It should be checked whether the bottle mouth is well sealed, whether the vacuum pump itself leaks, and whether the sealing ring at the rotating shaft is intact. A vacuum switch connected in series with an external vacuum tube can increase recovery and evaporation rate.
  2. Feeding: Using the system vacuum negative pressure, the liquid material can be sucked into the rotating bottle with the PTFE hose on the feeding port, and the liquid material should not exceed half of the rotating bottle. The instrument can be continuously fed. When feeding, please pay attention to: turn off the vacuum pump; stop heating; slowly open the feeding valve cock after the evaporation stops to prevent backflow.
  3. Heating: The instrument is equipped with a specially designed water bath. It must be energized after adding water. The temperature control range is 0-400 °C for reference. Due to the existence of thermal inertia, the actual water temperature is about 2 degrees higher than the set temperature, and the set value can be corrected when used. Temperature setting: Turn on the water bath pot, set the desired temperature, press the SET button, and the upper row displays SP.
  4. Rotate: Turn on the speed switch, adjust the knob to the optimal speed, and avoid the water vibration wave.
  5. Turn on the cooling water.
  6. Recovering the solvent: Turn off the vacuum pump, open the feed switch to deflate, and take out the solvent in the collection bottle.

    application steps of rotary evaporators

    application steps of rotary evaporators

the application steps of rotary evaporators.

  1. Prepare a white latex tube with a diameter of about 8 mm and a length of about 1500 mm. Also prepare a length of about 80 mm. The two latex tubes of the same size are used for vacuuming. Prepare a copper tee for use. Prepare one SHZ-D (III) circulating water vacuum pump. The water tank of the vacuum pump must be filled with water. The water is added to the head of the vacuum pump.
  2. First, we connect the prepared latex tubes with a length of about 80 mm to the ends of the tees. After connecting, we find the suction port of the circulating water vacuum pump. The identification of the suction port is: pumping I and pumping II, and connecting the two ends of the tee connecting the latex tube, respectively, and pumping I and pumping II.
  3. Prepare 2 hoses with a diameter of about 10 mm, a length of about 1000 mm, and four snap rings with a diameter of about 14. Find the inlet of the rotary evaporator condenser, and the water outlet. First we connect the hose to the outlet of the cryogenic coolant first, and the other end of the hose to the inlet of the rotary evaporator. Inlet identification method: Carefully observe the serpentine tube inside the glass condenser, observe each side separately, and find the mouth that communicates with the outside, and find the inlet and outlet. Usually located below is the water inlet, above which is the water outlet. We use another hose to connect the outlet of the rotary evaporator. The other end of the hose is connected to the inlet of the cryogenic cooling circulation pump. (The inlet and outlet are usually marked). Open the filling port cover of the cryogenic coolant circulation pump and clean the cold well. The coolant is added to the cooling tank in a ratio of 1:1:1. Note that press the power button and then press the cooling button to lower the desired temperature and then cycle.
  4. Install the rotating bottle and fix it with a clip. If there is a splash-proof joint, first attach it to the rotating bottle, and pay attention to the interface with vacuum grease. Turn on the vacuum pump and start rotating after a certain vacuum.
  5. Adjust the height and rotation speed of the distillation flask and set the appropriate water bath heating temperature.
  6. Stop spinning after steaming, and then pass the atmosphere. Then stop the pump and finally remove the distillation flask.
  7. Stop the low temperature coolant circulating pump, stop the water bath heating, and turn off the pump circulating water. Pour out the solvent in the receiving bottle and wash the buffer ball and receiving bottle.

    tocommon configuration rotary evaporator

    tocommon configuration rotary evaporator

The above mentioned text is a brief introduction operation steps of rotary evaporator. If you want to know more the rotary evaporators, please contact with henan lanphan. Henan lanphan is a qualified company, which boasts good reputation both home and abroad. For several years, we are dedicated to the manufacture of laboratory equipment and pipe fittings. If you want to know more more about this or possess the intention to buy it, please contact with us as soon as possible. We are willing to provide you as much information as possible.